QG135 Page 1 of 2 rev-2012-08-29
QuickGuide
Setup DucTester gauge for Codes (referencing 2009 IECC)
● Press the [On/Off] key.
● Press [Exit] to get to
the main screen.
● Press [Setup].
● Press [] until “Device Setup” is highlighted.
● Press [Enter].
The screen will now display all of the different types
of equipment that can be used with the DM-2.
To eliminate Devices not relevant to
duct testing, follow the steps
outlined below.
● Scroll down the list of Devices, one by
one, by pressing [] .
● Select “No” for all Devices except “Retrotec DU200”.
Scroll down, one by one, and turn the other devices
to “No” by pressing [].
● Now press [Exit] to return to the
“Setup” menu.
The gauge will now only display “Retrotec DU200”
on the main screen. If you want to use this gauge
for other Devices, select “Yes” for that Device on the
“Enable/Disable Device” menu.
Step 1: Setup for Device
Step 2: Setup Device Choices
This is what your gauge should look like before you begin
testing ducts. The following steps will show you how to
easily setup your gauge for duct testing to code
standards (the 2009 IECC - International Energy Conservation Code).
Code Required
Results
Correct Device
Range Congurations: It is recommended
to start on the Mid-Range Ring.
“No” means that the Device will not
display on main screen, “Yes” means
that it will display on the main screen.
www.retrotec.com Sales & Support: (855)738-7683 Internaonal: (604)732-0142 Made in Everson, WA USA
Vista de página 0
1 2

Resumo do Conteúdo

Página 1 - QuickGuide

QG135 Page 1 of 2 rev-2012-08-29QuickGuide Setup DucTester gauge for Codes (ref

Página 2 - Step 3: Setup Mode

Page 2 of 2 The “Mode Setup” allows you to select only the results needed for duct testing according to code (2009 IECC). Instead of doing

Comentários a estes Manuais

Sem comentários